Ultrasonic mist maker dispersed the water substructure produced fog nature and elegantly from high-frequency oscillation in atomization piece. No need any chemical agent. | |
Ultrasonic mist maker dispersed the water substructure produced fog nature and elegantly from high-frequency oscillation in atomization piece. No need any chemical agent. | |
Ultrasonic mist maker
Ultrasonic mist maker dispersed the water substructure produced fog nature and elegantly from high-frequency
oscillation in atomization piece. No need any chemical agent.
Popular usage
Common fault & treatment:
1.Check the plug is good, check the
power supply is good.
2.exchange the polarity of the power
supply is OK.
Normal power supply also power light is
on but no moisture.
The coating can be move from surface
of mist maker
many mist maker placed in same container
and not connected.
Troubles
Analysis
Treatment
No electricity in atomizer,no indicator light
1. power supply abornomal from atomizer.
2.The polarity of the power supply is reversed
water level of container is too low.
preapre enough water
Some nozzle cannot working
atomizer film damaged
replace the film
nozzle circuit damaged
back to supplier for repair.
small spray from nozzle
old film or damage
replace the new film
the liquid humidifying is corrosion
change the liquid
Connected all mist maker
Application Notice
1. Please choose DC46±2V, Rate: >300W.
2. Ring transformer must have alumimum heat sink,and prepare some thermal grease between rectifier bridge and alumimum heat sink.
3. more than one mist maker fixed in same tank,please conducted each other.
4. The fog produced from mist maker must remove by fan. Keep each mist maker have 600cm2 space. High temprature water will
shorten life of mist maker.
5. Mist maker loved neutral liquid (PH5~8). Acid can corrosion shell & film,alkaline liquid can effect fog, shorten the life of mist maker & film.
6. Do not damage water level switch in install, the water level switch will out of order if damaged.
7. Do not put the hand over the mist maker when working.
8. Do not let mist maker working out of water, please put the mist maker in water before power on.
Maintenace for mist maker
For your products long life and good effect, please read below insruction:
1.The mineral will build up on the shell or film after a long time service. It will effect the long life & fog.
We advise that you had better clean the mist maker each half an month. You can use soft cloth with alcohol.
Do not use any hard cloth for scrath mist maker or film.
2.Water quality will effect the long life of mist maker. We advise you that used clean water.
3.After long time service (3000 hours),the film life will be shorten, the atomiztion will less. Like this,
please replace the film.
Replace film as follows:
Power off first. Take out the atomizer from water and upside down the mist maker. When the water come out
from mist maker, use dry cloth clean the mist maker.Use tool open the end ring and take out the film and put
in the new film.