LIndustrial humidifier 360L
Industrial humidifier is a highly profeessional mechnical equipment. For the people are poorly aware of this, so the choose dehumidifier according the area of humidifiction when load the humidifier. For examples, the workshop, warehouse need special air-pure equipment, so they need special requirement for humidification.
product feature:
ITEM:CS360-001 MOISTURE REMOVAL:360 L/D(30℃ RH80%)
Power:380V/50HZ Cooling agent:R22/1350g*2
current rating:9.0A Rated power:4900W
Max current:10.6A Max power:6100W
Material:metal plated Applicable temperature:5-35℃
Products size:520×1200×1745 mm drainage: continuous water drainage
Products Function:
● Ambient temperature,humidity,timing display
● accuracy control dehumification by PC
● fault code display
● phase sequence protection
● defrost auntomatic,keep dehumidify effect
● Timing switch function;save worry save electricity
● buzzer voice guide
● Set high, low wind speed
● Turbo air duct system
● Automatic delay protection for compressor
● 3C certificate 2012010703573381
● China's Ping An insurance company
● Hitachi press
● Cycle timing switch function
● Inside spiral grain copper tube
● Thermal protection
Subassembly:
Application notice for dehumidifier:
1. The best temperature of dehumidifier: 15℃~38℃.
2. The door & window should closed when dehumidifying.It can get best effect.
3. The dehumidifier should fixed in the centre of room.And the air intake & air outtake must be keep ventilate.
4. The dehumidifier must placed flat, cannot incline.avoid dehumidifier failure.
5.dehumidifier do not place in the room that has corrosive gas,excessive dust. Please choose dehumidifier with anti-corrosion functionwhen used in corrosive gas room. Please clear or change filter when used in excessive dust room.
6. Reused must hold more 6 hours if dehumidifier have transportation.
maintenance procedure:
1. It can be use soap-suds for clearing if have dust on the surface of dehumidifier,do not use gasoline, benzoline, solvent,otherwise will paint removed, or discolor.
2. The filter screen must clear regular (once for two weeks).
3. The machine must clear regular (one for two months).
4. Please pull out the plug if long time no used.And pack the machine and keep in cool place.